Wall Height Elevation (~6 ft to 8 ft Max)
Existing ~6 ft low walls block daylight and trap heat. Raising load-bearing masonry by +2 ft to an 8 ft eaves height (plus roof pitch clearance) restores natural illumination and cross-ventilation.
Tisgaon Vidyalay (Est. 1993) • Khultabad, Chh. SambhajinagarTargeted civil rehabilitation at Tisgaon Vidyalay (500-student capacity)—raising low ~6 ft classroom walls to 8 ft for natural illumination and airflow, replacing leaking corrugated roof sheets, re-plastering walls, and laying bench-compatible Kota / Shahabad stone flooring.
Unedited site walkthrough at Tisgaon Vidyalay documenting corroded roof sheets, rainwater ingress points, and low ~6 ft classroom wall height prior to renovation.



Every classroom undergoes 9 standardized civil upgrades designed for rural durability, natural cross-ventilation, and heavy school bench usage.
Existing ~6 ft low walls block daylight and trap heat. Raising load-bearing masonry by +2 ft to an 8 ft eaves height (plus roof pitch clearance) restores natural illumination and cross-ventilation.
Worn-out, rusted corrugated steel sheets causing severe monsoon leakage are replaced with 0.50 mm pre-painted galvalume sheets mounted on reinforced MS purlins.
Hacking loose, flaking mortar and applying fresh 12–15 mm cement-sand plaster across newly raised masonry courses and eroded lower wall sections.
Replacing cracked, dusty cement floors with heavy-duty Kota / Shahabad stone slabs—preferred by rural schools for resisting impact and supporting heavy benches without cracking.
Replacing pitted, high-glare boards with a smooth, non-glare matte green chalkboard in an anodized aluminum frame for sharp visibility from back benches.
Replacing rusted hinges, stay rods, locking bolts, and damaged window panels so shutters open smoothly for cross-breeze and natural daylight.
Planing and re-aligning warped door shutters, upgrading heavy-duty butt hinges and aldrops, and applying protective primer and enamel coats.
Full primer coat, putty touch-up, and two coats of washable light-reflecting paint to brighten classroom interiors and weather-shield exterior walls.
Sealing top wall-to-roof joints with ridge flashing and cement coping, paired with 6-inch stone wall skirting to prevent dampness during wet mopping.
Calculated for one standard 20 ft × 20 ft classroom (400 sq. ft.) using prevailing Chhatrapati Sambhajinagar civil contracting rates. CSR partners can adopt 1 classroom or scale across multiple rooms.
| # | Renovation Item & Rural School Specification | Est. Quantity | Sambhajinagar Rate | Tentative Cost |
|---|---|---|---|---|
| 01 | Wall Height Raising (~6 ft to 8 ft max) +2 ft 9" brick/fly-ash masonry (1:6 mortar) & top coping band | 140 sq. ft. (net wall) | ₹110 / sq. ft. | ₹15,400 |
| 02 | Corrugated Sheet Roof Replacement 0.50 mm pre-painted galvalume sheets, MS purlin repair & J-bolt/ridge fixing | 460 sq. ft. (incl. eaves) | ₹110 / sq. ft. | ₹50,600 |
| 03 | Deteriorated Wall Plaster Repair Hacking loose plaster + 12–15 mm cement-sand plaster on raised & damaged walls | 500 sq. ft. | ₹36 / sq. ft. | ₹18,000 |
| 04 | Economy Natural Stone Flooring (Bench-Compatible) Heavy-duty Kota / Shahabad stone slabs (25–30 mm) on mortar bed + 6" skirting | 400 sq. ft. | ₹85 / sq. ft. | ₹34,000 |
| 05 | Blackboard Renovation (8 ft × 4 ft) Non-glare matte green chalkboard with anodized aluminum frame & wall mounting | 1 Unit (32 sq. ft.) | ₹6,500 / unit | ₹6,500 |
| 06 | Window Hinges, Panels & Door Refitting Replacement of worn hinges, tower bolts, aldrops, stay rods & minor shutter refitting | 1 Classroom (L.S.) | ₹4,500 / room | ₹4,500 |
| 07 | Interior & Exterior Classroom Coloring Primer coat, putty touch-up & 2 coats washable distemper / exterior emulsion | 1,100 sq. ft. | ₹15 / sq. ft. | ₹16,500 |
| TENTATIVE TOTAL PER CLASSROOM (400 sq. ft. • Material + Labour) | ₹1,45,500 | |||
Complete 7-point renovation of 1 Classroom (400 sq. ft.) with donor recognition plaque.
Complete renovation of 3 Classrooms (1,200 sq. ft.) serving ~150 students per shift.
Full wing rehabilitation of 5 Classrooms with milestone-linked Utilization Certificate.
SDG 4 • Target 4.a
Safe Learning Facilities
SDG 9 • Target 9.1
Durable School Infrastructure
SDG 11 • Target 11.c
Local Materials & Labour
Qualifies under Schedule VII, Item (ii) (promoting education through resilient school infrastructure). Implemented by Satyashodhak Mahila Vikas Mandal (Head Office: Chhatrapati Sambhajinagar; School: Tisgaon Vidyalay, Khultabad Tehsil).
Sponsor complete Classroom Renovation at ₹1,45,500 per classroom with full statutory compliance and milestone-linked Utilization Certificates.

Visual verification of rusted fasteners and perforated roof panels permitting rainwater entry directly above student seating rows.

Abraded cement floor surfaces generating fine dust particles and requiring complete vitrified tile overlay and wall dado protection.
MS structural trusses, purlins, 0.50 mm pre-painted galvalume sheets, insulation & guttering.
Sub-base leveling, anti-skid vitrified floor tiling (2,000 sq. ft.), and 4-ft wall dado skirting.
Funding Status: 0% Committed • 100% Open for CSR Grant
Mr. Navnath Adhane
Project HeadAll project receipts, vendor invoices, and tranche disbursements are recorded in Satyashodhak Mahila Vikas Mandal's ERP ledger for donor audit review.
Sponsor the complete Phase I restoration (₹11,00,000) or co-fund either the Roofing Package (₹6,80,000) or Flooring Package (₹4,20,000) with milestone-linked Utilization Certificates.